Ransburg, Troubleshooting guide, No. 2 process electric motor version - maintenance – Ransburg No. 2 Process Handgun Electric Motor User Manual

Page 45

Advertising
background image

Power line unplugged

Fuse(s) blown

High voltage cable failure; cable

crackles when system is on.

Operator holding applicator by the

barrel

Gun and power supply not grounded

Operator wearing gloves; operator

wearing rubber soled shoes

Operator is charged before picking

up the applicator

Metal shiel on high voltage cable is

broken

No. 2 Process Electric Motor Version - Maintenance

Ransburg

41

AH-13-01.1

General Problem

Possible Cause

Solution

ELECTRICAL (Cont.)

TROUBLESHOOTING GUIDE

(Cont.)

No High Voltage

Output

Plug in and verify available voltage.

See “Maintenance” section to replace

fuse(s).

Verify cable braid continuity from the con-

nector end to the opposite end with ohm

meter. Replace as required.

Mild Shock

When Picking

Up Applicator by

the Handle

Keep one bare had on the handle at all

times to ensure ground to the operator.

Ground power supply to true earth ground.

Remove rubber gloves or cut holes in the

palm of the glove where handle contact

can be achieved. Add grounding straps to

shoes if required.

Ensure operator has proper ground.

Verify cable braid continuity from the con-

nector end to the opposite end with ohm

meter. Replace as required.

Advertising