The green and yellow regions of the bar graph

meter indicate output current is in the optimum

range for maximum transfer efficiency. The red

region of the bar graph indicates high output current

causing decreased transfer efficiency.

Figure 39: Local/Remote Mode Button

>

If unit is in remote mode with no external

signal, the unit will not function. The unit

must be in local mode.

C A U T I O N

!

Local/Remote Mode Button

The 9060 Power Supply product line is designed

currently for applicators only. The mode should be

set to local for all Vector applicator applications.