TROUBLESHOOTING GUIDE

General Problem

Procedure

Solution

No Power

(Green Power Switch

Light Does Not Come

On and Displays Are

Blank)

No Displays

(Green Power Switch

Light Is ON, But One

Or All Card Displays

Are Blank)

1. 115/230 VAC source

switch on 24VDC power

supply set to wrong position

2. Improper AC input voltage

from control panel terminal

TB3-L to TB3-N

3. Improper AC input voltage

from control panel terminal

TB3-F2 to TB3-F1

4. Improper AC input voltage

from control panel terminal

SW1-A3 to SW1-B4

5. Improper AC input voltage

from control panel terminal

SW1-A4 to SW1-B3 with

switch on

6. Improper DC voltage from

TB2-1 to TB2-4 of 24VDC

power supply

7. Faulty wiring to any of

above

1. Defective Control Card

2. Misconnected or defec-

tive ribbon cable assembly

from the Control Card to

each Atomizer and Tem-

perature/Humidity Card

1. Set 24VDC power supply source switch to

proper position.

2. Check factory voltage from the external

fused disconnect.

3. Replace fuse F1 and/or F2.

4. Replace AC line filter LF1.

5. Repair or replace switch SW1.

6. Replace 24VDC power supply.

7. Secure any loose or disconnected wires.

1. Check for flashing red LED1 at upper left

corner of Control Card. If not flashing, cycle

AC power. If red LED1 still does not

flash, replace the Control Card.

2. Secure or replace ribbon cable assembly.

Replace the Control Board if no problem is

found with the ribbon cable.