Evolver Solventborne Robotic Atomizers - Maintenance

7. The o-ring [16] should be inserted into

the front of the bushing [14] and one of the o-rings

[15] installed onto the outside groove before the

bushing is installed.

8. Reassemble the remaining parts, as shown in

Figure 9, making sure that the alignment tab on the

bushing [14] lines up with the align groove in the

body [19].

9. Torque the seal carriage [13] to 30-35 lbs•in (4.0-

4.5 Nm).

10. If the u-cup needs to be replaced, assemble

on piston plate [9] and push both onto shaft, tighten

securely with piston nut [7], and install in body as

one assembly.

11. Assemble the remainder of the gun head as

stated earlier.

12. If the locking tab plug connection [24] needs

to be replaced, first remove the electrode spring

connector [23] by pulling straight out with a needle

nose pliers. If removed, the spring wire should be

replaced.

13. Remove socket head screw [22] and connec-

tion plug [24] from body.

14. Replace conductive compressable contact [25]

if necessary.

15. Reinstall the connection plug [24] into the body,

making sure the tabs on the bottom align

with

the notches in the body [19].

16. Insert and tighten the screw [22], making sure

the tabs remain inside the notches [24] in the body.

17. Insert the spring electrode wire [23] through

the hole in the screw using a needle nose pliers

on the straight wire portion. Carefully rotate and

push the wire through the screw hole and into the

compressable contact until the spring contacts the

screw head.

>

Use Caution as NOT TO scratch or raise burrs

on inside diameters of the parts.

C A U T I O N

!

AA-03-02.11