AdaptaFlow Node Adapter - Safety

2

2

2

2

2

A R E A

A R E A

A R E A

A R E A

A R E A

Tells where hazards

may occur.

H A Z A R D

H A Z A R D

H A Z A R D

H A Z A R D

H A Z A R D

Tells what the hazard is.

S A F E G U A R D S

S A F E G U A R D S

S A F E G U A R D S

S A F E G U A R D S

S A F E G U A R D S

Tells how to avoid the hazard.

Spray Area

Spray Area

Spray Area

Spray Area

Spray Area

Fire Hazard

Improper or inadequate opera-
tioning and maintenance pro-
cedures will cause a fire hazard.

Protection against inadvertent
arcing that is capable of causing
fire or explosion is lost if any safety
interlocks are disabled during
operation. Frequent power supply
shutdown indicates a problem in
the system requiring correction.

Fire extinguishing equipment must be present in the
spray area and tested periodically.

Spray areas must be kept clean to prevent the
accumulation of combustible residues.

Smoking must never be allowed in the spray area.

The high voltage supplied to the atomizer must be
turned off prior to cleaning, flushing or maintenance.

When using solvents for cleaning:

Those used for equipment flushing should have flash
points equal to or higher than those of the coating
material.

Those used for general cleaning must have flash
points above 100

°F (37.8°C).

Spray booth ventilation must be kept at the rates
required by NFPA-33, OSHA, and local codes. In
addition, ventilation must be maintained during
cleaning operations using flammable or combustible
solvents.

Electrostatic arcing must be prevented.

Test only in areas free of combustible material.

Testing may require high voltage to be on, but only as
instructed.

Non-factory replacement parts or unauthorized
equipment modifications may cause fire or injury.

If used, the key switch bypass is intended for use
only during set-up operations. Production should
never be done with safety interlocks disabled.

Never use equipment intended for use in waterborne
installations to spray solvent based materials.

The paint process and equipment should be set up
and operated in accordance with NFPA-33, NEC, and
OSHA requirements.