1

Quick Startup Guide

SETTING UP THE ISDN LINE

Before configuring the Express XL/XLT, ensure that the telephone service has
provided the switch type, service profile identification (SPID), and local direc-
tory number (LDN).

Example:

Switch Type

National ISDN-1

SPID1

20555512120100

SPID2

20555512130100

LDN1

5551212

LDN2

5551213

1.

Connect a VT 100 async terminal, or personal computer with a terminal
emulator running 9600 N-8-1, to the

MAINTENANCE

port.

2.

Hold down the

Control

key and press

R

; then press

Enter

to display the

top menu.

3.

Using the arrow keys and

Enter

key to navigate the menu, go to the

Con-

figuration/WAN/ISDN/Dial Line

menu. Enter the SPIDs, LDNs, and

switch type.

4.

Use the left arrow key or the

Escape

key to go back up the menu tree.

When asked to save ISDN parameters, type

y

.

5.

Connect the ISDN line to the RJ-45 jack labeled

ISDN BRI U

on the rear

panel.

6.

When the Loop LED remains solid, the Express XL/XLT is ready for call-
ing.

7.

If using a POTS Phone with the Express XLT, connect the POTS telephone
to the POTS port.

If the SPID(s) does not work or is unknown, try activating the ExpertISDN