FANS WITH PRESSURE SENSORS

INSTALLATION INSTRUCTIONS

OPTIONAL MOUNTING BRACKET

RI-PS FAN SERIES

TLD200-PS SERIES

PWS-PS SERIES

DRYER

Rubber Isolator

Suspension
Bracket

(Optional)

LINT TRAP

IMPORTANT:

ALL FANS EQUIPPED WITH PRESSURE SENSOR MUST
BE INSTALLED WITH SENSOR MOUNTED VERTICALLY
OR HORIZONTALLY. NEVER INSTALL PRESSURE SENSOR
BARB POINTING DOWNWARD.

Mounting Clamps

(Optional)

Pressure
Sensor

Barb

(Never Pointing
Downward)

120 V AC

Pressure
Sensor

Mounting

Clamps

(Optional)

> use for rigid duct,

complete with foam

rubber isolator.

Tubing

joel tantay 5.19.09

PWS-PS Series

NC

NO

C

RELAY

(10 Amp.)

NC

NO

C

FAN

1

2

3

LOAD

BLACK

WHITE

RED

NO

C

T I M E R

120V AC / 60HZ

POWER SUPPLY

WHITE

RED

BLACK

MAX. LOAD
1.0 Amp.

600 Sec. “ON”

60 Sec. “OFF”

Pressure

Sensor

BLACK

Wall

Switch

TLD200-PS & RI-PS SERIES

Typical wiring Diagram

TIMER

GREEN

BLUE

MOTOR

120 V AC

SW

RED

WHITE

LOAD

WHITE

BLACK

BLACK

BROWN

BLACK

CAPACITOR

BLACK

C

NO

PRESSURE

SENSOR

TO AVOID THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY,
TURN POWER OFF AT SERVICE PANEL BEFORE INSTALLATION
OR CLEANING OR SERVICING THIS UNIT.