INSTALLATION & OPERATION

1. These units are not to be used to exhaust hazardous or explosive gases.

2. To avoid damage to motor and impeller, keep construction materials such as dry wall spray,

construction dust, construction debris, etc. off from power units and ducts leading to units.

CAUTION:

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY,
PLEASE OBSERVE THE FOLLOWING:

1. Installation of these units and the corresponding electrical wiring must be done by a qualified person and
be in accordance with all municipal and national codes and standards, including those related to fire rated
construction.

2. Use this units only for intended applications and in the manner indicated by the manufacturer. If you have
any questions please contact the manufacturer at the address or telephone number listed here in the
manual.

3. Before wiring, servicing or cleaning the units, switch power off at the service panel and lock it. If service
panel is unlocked others could turn the power on unexpectedly and cause fatal electric shock to the
installer or service person.

4. When cutting or drilling into wall or ceiling, make sure that you do not damage electrical wiring and other
hidden utilities.

5. Always vent units to the outdoors, NOT into unventilated spaces such as garages, attics, crawl spaces, etc.
Use roof cap, wall cap or wall box.

6. The Fan blade must be checked at least twice annually for dust accumulation.

7. All Fans should have a backdraft damper at outlet.

NOTE: USE AS FEW ELBOWS AS POSSIBLE

INSULATION -

Minimum 5 Feet

(1” Thick)

Rigid Duct Only

SLOPE

BAFFLE

GRILLE

CAULKING

LEAK - PROOF
WALLBOX

NEOPRENE
BACKDRAFT
DAMPER

- 3 SIDES ONLY, NOT ON BOTTOM

(IF CAULKING ALL 4 SIDES, MUST

HAVE DRAINING HOLES.)

WALL

Rubber Isolator