Hrv and erv typical installations, Semi ducted system ( for superior series only), Fully ducted system – Reversomatic Economy Series User Manual

Page 9

Advertising
background image

HRV and ERV Typical Installations

7

2 Single Vents
SVE-50 and SVI-50
Shown, 5 ft. minimum
gap between vents

“Fresh Air/ Exhaust Air
Vents Installation”

HRV/ERV (SUPERIOR)

RETURN-AIR DUCT

FURNACE

Wall Cap
Exhaust/Intake
WCE-5, WCI-5
shown

• This installation enables stale air to be drawn from the
poorest air quality areas of the home (washrooms & kitchen)

Double Vent with Extruded Aluminum Grille
DVG200 shown “Fresh Air/Exhaust Air Vent installation”

from washrooms
and kitchen

Semi Ducted System ( For Superior series only)

• It is recommended that the furnace blower run
continuously or HRV/ERV operation be interlocked
with the furnace blower to evenly distribute the fresh
air throughout the house.

• A backdraft damper is required in the fresh air exhaust side
to prevent outdoor air from entering the unit when the
Furnace / Air handler is running and the unit is in Standby,
OFF or in defrost mode.

Note: (For Semi Ducted System only)

Typical Installations for House

Installation Options for High-Rise Condominium

Fully Ducted
System

With Fan-Coil
System

FRESH AIR
EXHAUSTED AIR

Balancing Box

Fan-coil Unit

HRV/ERV

Fan-coil Unit

HRV/ERV

NOTE:

For Project Series use single bathroom
exhaust fan or inline bathroom exhaust fan
(for two washrooms).

This is a stand alone HRV/ERV system which is not
connected to a force air system. Stale air is drawn from
key areas of the home (bathroom, kitchen) while fresh
air is supplied to main living areas.

Fully Ducted System

(for Superior series only)

Note:

All Vents must be installed

min. 5 ft away from sidewalls.

Balancing Box

With Fan-Coil
System

Fully Ducted
System

Fan-coil Unit

HRV/ERV

Fan-coil Unit

HRV/ERV

Project series shown

Superior / Project Condo Series Shown

HRV/ERV (SUPERIOR)

Model #

RHRV-S100A

RHRV-S100P
RERV-S100

RHRV-C100A
RHRV-C100P
RERV-C100

Model #

RHRV-P100A

RHRV-P100P
RERV-P100

Advertising