Five Year Limited Warranty

Maple Chase Company

warrants to the original contractor installer or

to the original consumer user, each new Maple Chase thermostat to be
free from defects in materials and workmanship under normal use and
service for a period of five (5) years from date of purchase. This warranty
does not cover batteries, damage caused by batteries, damage resulting
from improper installation, alteration, misuse or abuse of the thermostat
occurring after the date of purchase.

Maple Chase Company

agrees to repair or replace at its option any

thermostat under warranty provided it is returned within the warranty
period, postage prepaid, with proof of the date of purchase. Cost of ther-
mostat removal or reinstallation is not the responsibility of Maple Chase
Company.

Repair or replacement as provided under this warranty is the exclusive
remedy of the consumer.

Maple Chase Company

shall not be liable for

any incidental or consequential damages for breach of any express or
implied warranty on this product, or under any other theory of liability.
Except to the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose on this product is limit-
ed to the duration of this warranty.

Some states do not allow the exclusion or limitation of incidental or con-
sequential damages, or allow limitations on how long an implied warranty
lasts, so the above limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.

12

Maple Chase Company
2820 Thatcher Road
Downers Grove, Illinois 60515
United States of America

NOTE: Installer must place jumper
between ”W“ and ”Y“ terminals.

Hot

Compressor

Contactor

Transformer

24 VAC

120 VAC

HEAT PUMP WITH

COOL ACTIVE

REVERSING VALVE

RH

T

H
E
R

M
O

S
T
A
T

RC

W

Y

B

O

G

Reversing

Valve

NOTE: Installer must place jumper
between ”W“ and ”Y“ terminals.

Hot

Fan

Relay

Compressor

Contactor

Transformer

24 VAC

120 VAC

HEAT PUMP WITH

HEAT ACTIVE

REVERSING VALVE

RH

T

H
E
R

M
O

S
T
A
T

RC

W

Y

B

O

G

Reversing

Valve

NOTE: Factory
Installed Jumper

NOTE: Factory
Installed Jumper

Fan

Relay

Wiring Diagrams (cont’d)