4. Remove the cover using a coin or screwdriver (Figure 3). Set aside.

5. Place thermostat against the wall at desired location. Make sure

wires will feed through opening (Figure 4) on base of thermostat.

6. Mark placement of mounting holes (Figure 4). Set base aside.

7. If mounting on drywall, tap plastic anchors into wall.

NOTE: Enclosed plastic anchors do not require a drilled hole
for drywall.

8. If mounting on a surface other than drywall, drill the marked holes

using a 3/16" (5mm) drill bit.

9. Align base with plastic anchors and feed wires through opening.

10. Secure base to wall with supplied screws. NOTE: The thermostat

will mount horizontally on a single gang junction box.

11. Strip end of wires 5/16” (8mm) if needed.

12. Terminal screws are already loose and ready for wire insertion.

Insert wires into terminal strip (Figure 4) matching the label to the
corresponding terminal (see Wiring Diagrams). Tighten screws.

4

heat off cool

hold

vac

prog

run/set hold

temp

clock

set

auto on

MON

°

F

Figure 3

RC

RH

G

O

B

Y1

W1

ELEC GAS

°

F

+

+

Figure 4

Mounting Holes

110-1162.qxd 6/9/05 10:44 AM Page 4