15. Set the GAS/ELEC switch to either GAS for a gas/oil heating

system or ELEC for an electric heating system (Figure 6).

16. Set the HP/NON-HP switch to either the HP for heat pump or

NON-HP for furnace applications (Figure 6).

17. Install two AA Energizer brand batteries or equivalent into

battery compartment as shown (Figure 6).

18. Replace thermostat cover by snapping into place.

6

RESET

NON-HP

HP

ELEC

GAS

ROOM

°F

OFF

NON-HP/HP
Switch

GAS/ELECTRIC

Switch

+

-

+

-

Figure 6

TERMINAL LEGEND - 9400

TERM

EQUIPMENT TO CONNECT

REQ?

TERMINAL FUNCTION

Rh

24VAC hot connection

Yes

For input of 24VAC hot
side of heat transformer

Rc

24VAC hot connection

Yes

For input of 24VAC hot
side of cool transformer

W

Heat connection

Yes*

Energizes on a call for
heating

Y

Compressor Connection

Yes*

Energizes on a call for
cooling

B

Accessory**

No

Energizes when in the
HEAT mode

O

Accessory**

No

Energizes when in the
COOL mode

G

Indoor fan connection

Yes

Energizes with Y & W
terminals or with FAN
option switched to the
ON position

* This thermostat can be used as a heat only or cool only thermostat therefore it is not always

necessary to use both Y and W.

**The O and B terminals are accessory terminals that typically are used for heat pump applications.