Operating manual, Troubleshooting guide, Pump specifications – Robinair Model 15401 User Manual

Page 6

Advertising
background image

Troubleshooting guide

This pump has been designed for dependable

use and long life. If something should go wrong,

however, the following guide will help you get the

pump back into service as quickly as possible.
If disassembly of the pump is required, please

check your warranty. The warranty may be voided

by misuse or customer tampering that results in

the pump being inoperable.
Failure to start
Check line voltage. Robinair pumps are designed

to start at +10% line voltage (loaded) at 0

o

C. At

extremes, however, switching between the start

and run windings may occur. When starting the

pump in cold temperatures, verify the Iso-Valve

and inlet port are open to free air.
Oil leakage
1. Verify the oil is not a residual accumulation

from spillage, etc.

2. If leakage exists, the module cover gasket

or the shaft seal may need replacing.

Follow the instructions supplied with the

seal replacement kit, part number 15367. If

leakage exists in the area of the drain plug,

reseal the plug using a commercial pipe

thread sealer.

Failure to pull a good vacuum
1. Verify the Iso-Valve on the pump is in the

OPEN position, and the gas ballast knob is

tightly sealed.

2. Verify the vacuum gauge and all connections

are in good conditon and leak-free. Confirm

leakage by monitoring the vacuum with a

thermistor gauge while applying vacuum

pump oil at connections or suspected leak

points. Vacuum will improve briefly while the

oil is sealing the leak.

3. Be sure the pump oil is clean. A badly

contaminated pump may require several oil

flushes. See OIL CHANGE PROCEDURE.

4. Verify the oil is at the correct level. For

maximum pump operation, the oil must be

even with the OIL LEVEL line on the sight

glass when the pump is running. See OIL

CHANGE PROCEDURE. Do not overfill.

Operating temperatures cause the oil to

expand, so it will appear at a higher level than

when the pump is not running. To check the

oil level, start the pump with the inlet capped.

Check the oil level in the sight glass. Add oil if

necessary.

Pump Specifications

Model 15401

Frequency Range .................................... 50-60 Hz
Free Air Displacement .........................4 cfm/60 Hz

..................................................94 l/m @ 50 Hz

................................................ 113 l/m @ 60 Hz
Stages ..................................................................2
Motor Speed .............................1425 rpm @ 50 Hz

.............................................1725 rpm @ 60 Hz
Voltage Range ......................................110V–115V

........................................................ 220V–250V
Factory Micron Rating .......................... 15 microns
Approximate Oil Capacity ............................ 400 ml
Weight ........................................................... 13 kg
Width ....................................................... 14.29 cm
Height ........................................................ 24.6 cm
Length........................................................... 40 cm
Intake ....................................

1

/

4

" and

1

/

2

" SAE MFL

Min. Starting Temp. (at 90% voltage) ............... 0

o

C

Motor Size ............0.25kW (

1

/

3

HP) Capacitor Start

Operating Temp. ............................................. 68

o

C

Models 15601/15603/15605

Frequency Range .................................... 50-60 Hz
Free Air Displacement .........................6 cfm/60 Hz

................................................142 l/m @ 50 Hz

................................................170 l/m @ 60 Hz
Stages ..................................................................2
Motor Speed .............................1425 rpm @ 50 Hz

.............................................1725 rpm @ 60 Hz
Voltage Range ......................................110V–115V

........................................................ 220V–250V
Factory Micron Rating .......................... 15 microns
Approximate Oil Capacity ............................ 400 ml
Weight ........................................................... 13 kg
Width ....................................................... 14.29 cm
Height ........................................................ 24.6 cm
Length........................................................... 42 cm
Intake .............................

1

/

4

",

3

/

8

", and

1

/

2

" SAE MFL

Min. Starting Temp. (at 90% voltage) ............... 0

o

C

Motor Size ...........0.25 kW (

1

/

3

HP) Capacitor Start

Operating Temp. ............................................. 68

o

C

Notes:

1. All motors are internally protected (automatic

reset).

2. Operating temperatures are typical for normal

operating conditions.

3. Model 15603 has a bipolar side grounded plug.

4. Models 15405 & 15605 have Australian plugs.

Because of ongoing product improvements, we reserve the right to

change design, specifications, or materials without notice.

Operating Manual

6