Robinair 11910 Digital RefRigeRant gauge User Manual

Robinair Equipment

Advertising
background image

D

igital

R

efRigeRant

g

auge

This product is a convertible pressure gauge that

measures pressure and then displays results and

temperature on the LCD.

Setup

1. Press and hold the

ON / TARE button for

two seconds. All positions on the gauge are

illuminated for two seconds.

WARNING

• Wear safety goggles when working

with refrigerants. Refrigerants can

cause eye injury.

• Disconnect hoses using extreme

caution. Pressurized refrigerant may

be present in hoses. Point hoses away

from you and anyone nearby.

Instructions

Note: If

0.0 does not appear on the display, the

calibration procedure was not successful. Turn OFF

the gauge by pressing and holding the

ON / TARE

button for two seconds. Press the

ON / TARE button

again to turn the gauge ON and recalibrate (repeat

Step 2). It may be necessary to repeat this procedure

until the gauge is calibrated.

Installing the Gauge

1. Press and hold the

ON / TARE button for two

seconds to turn the gauge OFF before installation.

2. Install the gauge by using a wrench on the

gauge’s brass fitting.

cAuTION: Do NOT

tighten the gauge by hand; this will damage

the gauge and void warranty.

3. Press the

ON / TARE button. All positions on

the gauge illuminate for two seconds; then

the display changes to the last stored features

(units of pressure / temperature and type of

refrigerant) along with the current pressure

and temperature reading.

4. Select type of refrigerant by pressing the

R

button to scroll through the choices. Pause

when the correct refrigerant is displayed on

the gauge face.

To display only pressure, scroll through the

refrigerants until

---- is displayed.

Note: When a refrigerant is chosen, if pressure

is higher or lower than what is defined for that

type of refrigerant, the gauge displays

Or in the

temperature field. “Or” = out of range.

5. When testing is complete, turn OFF the gauge

by pressing and holding the

ON / TARE button

for two seconds.

If left ON, the gauge automatically shuts

OFF after 10 minutes of displaying a stable

pressure reading.

2. The gauge must be calibrated before use. With

the gauge turned ON and no pressure applied,

press the

ON / TARE button two times. The

gauge displays

0.0, and is now calibrated and

ready for use.

888.8

PSI BAR kPa kg/cm

2

8888

888

F

C

R

inHg

mmHg

0.0

PSI

401A

-16

F

R

3. Select unit of measure

by first removing

the rubber boot from

around the gauge. Use

the tip of a pencil to

press the units button

while watching the

LCD display. Pause when

the correct unit is displayed

on the gauge face.

42.0

PSI

408A

14

F

R

4. Select unit of temperature by using the tip

of a pencil to press the units button on the

back of the gauge for two seconds until the

temperature indicator on the LCD begins to

flash. The gauge is now in temperature unit

selection mode.

Press the units button again to cycle between

between Celsius or Fahrenheit. Once the

desired selection has been made, press and

hold the units button again for two seconds

until the indicator on the LCD begins to flash.

This exits temperature unit selection mode.

Pressing the units button now will adjust the

pressure units displayed on the LCD.

units