Element replacement, Quick change element replacement – Robinair 14450 Heat Gun User Manual

Page 8

Advertising
background image

©2000 Robinair, SPX Corporation

6

QUICK CHANGE ELEMENT REPLACEMENT

1. UNPLUG the heat gun.

2. Turn outer shield counterclockwise and pull away from housing.

3. Loosen bolt (but do not remove) and nut on the inner shield and

rotate clockwise until the locking knob on the housing is visible.

4. Remove the three (3) screws from the cover.

5. Lift back of cover and gently slide away from inner shield.

NOTE: Wiggle the cover gently back and forth to help in remov-
ing.

6. Disconnect the two female terminal connectors from the old

element and pull the element out of the inner shield.

7. Take the bolt and porcelain tubes out of the old element.

8. Remove old mica from the inner shield.

9. Reassemble the bolt through the new element using one spacer on

each side and also on the nut, but do not tighten.

10. Using the new piece of mica, wrap it around the new element.

NOTE: Start wrapping mica below the porcelain tubes.

Element Replacement

Advertising