Robinair 17607 Universal А-C FlUsh Fitting Kit User Manual

A/c f, Installation of the sealing cone

Advertising
background image

17607 U

niversal

a/C F

lUsh

F

itting

K

it

119366 (Rev. C, April 11, 2014)

© Bosch Automotive Service Solutions LLC

WARNING

Wear protective equipment, including

safety goggles, when working with

refrigerants and solvents. Refrigerants

and solvents can cause injuries.

Do not use any solvent containing alcohol, lacquer

thinner, brake cleaner, or any other non-approved

solvent.

Do not look into the component to observe air flow

- injury may result!

Equipment must be operated by qualified personnel.

Operator must be familiar with air conditioning and

refrigeration systems, solvents, and the dangers of

pressurized components.

The operator is responsible for complying with any

and all applicable laws and regulations governing

the use of this equipment, as well as the disposal

of used solvents, oil, equipment, and components.

These instructions are intended as guidelines for general
operation of the Universal Flush Fitting Kit. Follow
the vehicle manufacturer’s instructions for flushing
A/C systems.

The clamp assemblies and support plates included in
this kit can be installed on most A/C line or tube ends
for attachment of the flushing apparatus being used.

The support plates are slotted to allow for different size
tubes or line nuts to be supported against the lower
end of the sealing clamp. The chamfered area on the
support plates allow the flared end of the tubes to sit
level. This way the sealing cone can be seated without
slipping or damaging the end of the tube.

Seating of the sealing cone into the fittings or tube
ends does not require the use of wrenches or other
tools. Sealing cones damaged by tools must be replaced.

Installation of the Sealing Cone:

1. After selecting the correct support plate to fit

the tube or line fitting, tighten the clamp screw
until the cone is seated tightly against the end of
the tube or line fitting on the A/C component.

2. While holding the clamp screw by hand, rotate

the forcing nut an additional 1/8 to 1/4 turn. This
provides a leak-tight seal for the flushing operation.

To remove the clamp assembly, hold the clamp screw
and back off the forcing nut to free up the sealing cone
without damaging the end of the cone.

When using adapters on a tube or fitting that is too
small for the sealing cone to enter, replace the cone-
shaped seal with the concave seal.

To replace the sealing cone, hold the forcing nut and
back out the clamp screw until the cone is pulled out
the end of the clamp screw. Insert the desired sealing
cone into the end of the clamp screw, and tighten the
screw until the cone bottoms in the screw, using the
non-slotted support plate against the end of the cone.
CAUTION : Do NOT use pliers or other tools to twist

the sealing cone out of the clamp screw, because it

could damage the sealing cone.

Included in this Kit:

(2) Clamp Assembly
(2) Support Plate (1/2" OD tube)
(2) Support Plate (5/8" OD tube)
(2) Support Plate (3/4" OD tube)
(2) Support Plate (7/8" OD tube)
(2) Support Plate (No slot)

Clamp Screw

Forcing Nut

Sealing Cone

Clamp Assembly

Support Plate

Because of ongoing product improvements, we reserve the right

to change design, specifications, and materials without notice.

Toll-free Technical Support Line:

1-800-822-5561

in the U.S. and Canada

In all other locations, contact your local distributor.

%

655 Eisenhower Drive

Owatonna MN 55060

Customer Service: 1-800-533-6127

Fax : 1-800-322-2890

Technical Service : 1-800-822-5561

Fax : 1-866-259-1241

www.robinair.com

Advertising