Ronan X54-3302 User Manual

Ronan Equipment

Advertising
background image

Page 1 of 2

Rev. 0

A Family of

Products!!!

Transmitters

Alarm Trips

I/I Isolators

Ronan Engineering Company

Ph: 800-327-6626 Fax: 818-992-6435 E-mail: [email protected] Web: www.ronan.com

High Density Dual Channel Packaging

Field Configurable Options Including:

four (4) RTD types, seven (7) standard input spans

with selectable zero offsets (for non-linearized ranges only)

Full Input/Output/Power and Channel Isolation

Front Panel Power/Sensor Fail LED Indicator

Front Access to Zero and Span Adjustments

Standard 35 mm DIN Rail Mounting

DESCRIPTION:

The X54-3302 is a dual channel RTD transmit-

ter powered by 24 vdc. Features include: two piece plug-in connectors
for easy wiring and maintenance; Power/Sensor Fail LEDs; field con-
figurable ranges and RTD types; optional linearized outputs; full 1000
vac isolation; and front panel access to ZERO and SPAN adjustments.
RFI protection, wide operating temperature, and high accuracy are
standard features. Custom inputs, outputs, scaling and linearization are
available from the factory.

RTD Transmitters - Field Configuration Options - High Density DIN Rail Packaging

X54-3302

Dual Channel Universal RTD Transmitter

ISO 9001

REGISTERED

SPECIFICATIONS:

Input:
RTD sensor types: 100 ohm platinum, 120 ohm nickel,

10 ohm copper.
(linearized outputs available for Platinum or Nickel only)

Input Impedance:

> 100 K ohms.

Outputs: 4-20 mA or 0-20 mA into 650 ohm loads

1-5 V, 0-5 V with 250 ohm output impedance.

Span Adjustment:

Front-accessible, multi-turn, infinite resolution potentiometer
permits minimum +/- 5% adjustment.

Zero Adjustment:

Front-accessible, multi-turn, infinite resolution potentiometer
permits minimum +/- 5% adjustment

Sensor Failure Response:
Red front-panel LED indication with upscale drive standard.
Calibrated Accuracy:
+/- 0.1% of span (linearization errors additional on large

span applications, consult factory )

Isolation:
1,000 vac between channels, input and output.
Input and output circuits isolated by transformers.

Common Mode Rejection:

> 120 dB, DC at 60 Hz.

Common Mode Voltage:
1000 volts peak AC maximum without damage.
Ambient Temperature Coefficient:
Ambient temperature range: 32 to 158

°

F (0 to 70

°

C).

Gain: < +/- 0.01 % /

°

F.

Zero: < +/- 0.01 % /

°

F.

Ambient Temperature Range:
Operating: -20 to 158 F (-25 to 70

°

C).

Storage: -40 to 158 F (-40 to 70

°

C).

Power Supply Range:
18 to 30 vdc (Max. current draw = 190 madc @ 24 vdc)
Radio Frequency Effects:

< 0.4 mV (referred to input) + 0.2% of span (referred to out-
put) when exposed to 5W transmitter with frequency range
20-460 MHz at a distance of 1 m.

Calibration:
Typically, factory calibrated to customer specified ranges.

Customer configurable for non-linearized applications.

Terminals:

High temperature polyester type, wire size 12 AWG max., 10
A max., 300 V max.

Specifications apply at 23 +/- 2°C (74 +/- 2°F) unless otherwise specified, and are subject to change without notice,

Advertising