Ronan X54-3212 User Manual

Ronan Equipment

Advertising
background image

Page 1 of 2

Rev. 1

A Family of

Products!!!

Transmitters

Alarm Trips

I/I Isolators

Ronan Engineering Company

Ph: 800-327-6626 Fax: 661-295-6063 E-mail: [email protected] Web: www.ronan.com

High Density Dual Channel Packaging

Field Configurable Options Including:

(6) T/C types, volt, mV or mA inputs + (7) std. input spans

with selectable zero offsets (for non-linearized ranges only)

Ideal for Dual Channel I-to-I Isolator Applications

Max. Loop Load = 700 ohms at 24 vdc Loop Power

Full Input/Output/Power and Channel Isolation

Standard 35 mm DIN Rail Mounting

DESCRIPTION:

The X54-3212 is a dual channel transmitter

powered by the output 4-20 mA current loop. Features include: two

piece plug-in connectors for easy wiring and maintenance; internal

cold junction compensation for T/C inputs, field configurable input

types and ranges; optional linearized outputs; full 1000 vac isolation;

and front panel access to ZERO and SPAN adjustments. RFI protec-

tion, wide operating temperature, and high accuracy are standard fea-

tures. Custom inputs, outputs, scaling and linearization are available

from the factory.

T/C, volt, mV, mA Transmitters - Field Configuration Options—DIN Rail Mounting

X54-3212

2-Wire (output loop powered) Dual Ch. Universal T/C, V, mV, mA Transmitter

ISO 9001

REGISTERED

SPECIFICATIONS:

Inputs:

Thermocouple type E, J, K, T, R, S, or mV, volt, mA

(linearized outputs available for thermocouples only)

Input Impedance:

T/C or mV > 100 M ohm; volts = >550 K ohm

mA = 10 ohm

Outputs:

4-20 mA into 700 ohms with 24 vdc loop power

I.e.: Max Rload = (Vloop supply– 10 vdc) / 20 mA

Span Adjustment:

Front-accessible, multi-turn, infinite resolution potentiometer

permits minimum +/- 5% adjustment.

Zero Adjustment:

Front-accessible, multi-turn, infinite resolution potentiometer

permits minimum +/- 5% adjustment

Sensor Failure Response:

Red front-panel LED with upscale drive or down scale drive

(mA input are down scale only)

Calibrated Accuracy:

+/- 0.1% of span (linearization errors additional on large

span applications, consult factory )

Isolation:

1,000 vac between channels, input and output.

Common Mode Rejection:

> 120 dB, DC at 60 Hz.

Common Mode Voltage:

1000 volts peak AC maximum without damage.
Ambient Temperature Coefficient:

Ambient temperature range: 32 to 158

°

F (0 to 70

°

C).

Gain: < +/- 0.01 % /

°

F.

Zero: < +/- 0.005 % /

°

F.

Ambient Temperature Range:

Operating: -20 to 158

°

F (-25 to 70

°

C).

Storage: -40 to 158

°

F (-40 to 70

°

C).

Power Supply Range:

10 to 40 vdc (max. allowable at X54)

(reverse polarity protected)

Radio Frequency Effects:

< 0.4 mV (referred to input) + 0.2% of span (referred to out-

put) when exposed to 5W transmitter with frequency range

20-460 MHz at a distance of meter.

Calibration:

Typically, factory calibrated to customer specified ranges.

Customer configurable for non-linearized applications.

Terminals:

High temperature polyester type, wire size 12 AWG max., 10

A max., 300 V max.

Specifications apply at 23 +/- 2°C (74 +/- 2°F) unless otherwise specified, and are subject to change without notice,

Advertising