ADDENDUM FOR MODEL SAM2C-24 MAGNALOCK

This addendum is intended as an introductory supplement to the Securitron Model SAM,

SAM2 Shear Aligning Magnalock Manual (P/N 500-10440) and addresses installation and
operating information specific to the “C” Senstat version of Magnalocks.

1.

INTRODUCTION

Securitron has now implemented the new “SAM2C-24”, Form-C style Mini Shear Aligning Magnalock. It
was created to add an additional door status feature. The door status functions when the door is closed

and the Magnalock is under power. The strike contact to the Magnalock face reports a two wire connection
continuity completing door status. The features for the SAM2C-24 are as follows:

 The Form-C feature allows hook-up for door monitoring capabilities

 Dual lock face geometry for lock face isolated contact points

 Field retrofits dimensionally and electrically to its related model types

 Maintains required holding force requirements

 Form-C Operational Specifications: 1 Amp @ 30VDC Maximum

2.

ELECTRICAL WIRING

Form-C lock wiring provides isolated closure with the Green and White when the lock is on and the strike is
secure. The wiring diagram is illustrated below.

COM

-

+

NC

SAM2C-24

C

NC

NO

CONTROL

CONTACTS DRY

INCLUDED

DIODE

RED

WHITE

GREEN

-

+

120

VAC

IN

VDC
OUT

24VDC POWER

SUPPLY

NOTE: LOCK IS DEPICTED IN

THE SECURE CONDITION

24VDC OUPUT WHEN LOCK IS SECURE
USE TO ACTIVATE RELAY
FOR DRY CONTACT OUTPUT

3.

DOUBLE DOOR STATUS REPORTING

Additional information for “Double Door Status Reporting” can be found in Section 3.6 of the Securitron
Model SAM, SAM2 Shear Aligning Magnalock Manual or in Section 3.6 of the Securitron Magnalock Manual.

4.

TROUBLESHOOTING INFORMATION

Additional reference information can be found under “Troubleshooting Information” in Appendix A of the
Securitron Model SAM, SAM2 Shear Aligning Magnalock Manual or in Appendix A of the Securitron

Magnalock Manual.