1. SPECIFICATIONS

MECHANICAL ELECTRICAL/ENVIRONMENTAL

Keypad Dimensions:
2” x 2-3/4” x 1/4” (Width x Length x Height

off of stainless steel faceplate)

Stainless Steel Faceplate Dimensions:
2-3/4” x 4-7/16” x 5/32” (Width x Length x
Height)

Back Board Dimensions:
1-29/32” x 2-13/16” x 1-1/16” (Width x
Length x Height off of stainless steel
faceplate)

Power Supply:
12/24VDC @ 100 milliamps maximum

12/24VAC @ 325 milliamps maximum

Relay Contacts:
Maximum 5 amps @ 30 volts

Environmental:

Operating: -10°F [-23°C] to 140°F [60°C]
Storage: -10°F [-23°C] to 150°F [65.6°C]
Humidity: 0% to 95% RH

2. INSTALLATION

SURFACE MOUNT WALL BOX

 Separate the wall box cover and base.

 Remove rectangular knockout in the center of the base.

 Cut out opening in the wall that will be used to route the wires through.

 Mount base to wall over wire opening using the #6 sheet metal screws and plastic anchors.

 Mount DK-12 to cover with either tamper resistant #6 screws (recommended) or #6

conventional screws. See Section 7 (Programming) before securing DK-12 in place.

 Pull wires through wall/center of base and connect to DK-12 wiring terminals (see Section 3

for wiring instructions).

 Push the wall box cover onto the base until it snaps into place.

FLUSH MOUNT WALL BOX

 Cut out opening in wall to mount box into.

 Route wiring through one of the four knockouts in the back of the box.

 Push the box into the wall and secure in place using the two swing clamps.

 Connect wires to DK-12 wiring terminals (see Section 3 for wiring instructions).

 Mount DK-12 to box with either tamper resistant #6 screws (recommended) or #6

conventional screws. See Section 7 (Programming) before securing DK-12 in place.


The DK-12 can be used outdoors with the optional rain cover (Securitron part #WCC) which will

allow the DK-12 to be mounted in outdoor locations not directly exposed to rain or snow. When
used outdoors you must supply a weatherproof, gasketed wall box (available from Securitron
under part #WBB).

3. WIRING

Wiring Terminal Connections:
1. ‘AC/DC+’ One AC supply lead or positive DC supply lead.
2. ‘AC/DC-’ Other AC supply lead or negative DC supply lead.
3. ‘NC’ Normally closed relay contact.
4. ‘COM’ Common for relay contacts.
5. ‘NO’ Normally open relay contact.

6. ‘SRC’ Supply for REX signal.
7. ‘REX’ REX Signal input.

NOTE: Each terminal is provided with a marking in front of it for
easy reference.

1 2 3 4 5 6 7

DK-12

Back Side

Wiring

Terminals

AC

/DC

+

AC

/DC

-

NC

COM

NO

SR

C

RE

X