Securitron EPTL-SC User Manual

Securitron For Home

Advertising
background image

Securitron Magnalock Corp.

www.securitron.com

ASSA ABLOY, the global leader

Tel

800.624.5625

[email protected]

in door opening solutions


© Copyright, 2011, all rights reserved

PN# 500-14260

Page 1

Rev. C, 08/11

EPTL-SC SERIES ELECTRICAL POWER TRANSFER (LONG) FOR SWING

CLEAR HINGED DOOR APPLICATIONS - INSTALLATION INSTRUCTIONS

1 DESCRIPTION
The EPTL-SC allows an electric lock or exit device, such as a Securitron Touch Sense Bar or
Touch Sense Handle, to be installed while concealing and protecting the cabling between the
hinged edge of a door and its door frame. The EPTL-SC provides a flexible steel shield conduit

which is approximately 5/16” [7,9mm] I.D. (inside diameter). The EL-EPTL-SC is furnished with
a wire harness already installed which includes ElectroLynx® connectors at each end.
The EPTL-SC power transfer device has been specifically designed and configured for installation
on doors using Swing Clear type hinges.

Note: The EPTL-SC will NOT work on doors utilizing center pivot type hinges.


2 PRODUCT OVERVIEW

Upon unpacking this product, an inventory should be made to ensure
that all of the required components have been included. Along with
these instructions and the installation template, this product should
include the following items:


2.1 HARDWARE
8X 8X

4X

4X

Phillips Flat Head

#6 X 5/8” Type “A”

Phillips Flat Head

6-32 X 3/8” Type “F”

Phillips Pan Head

8-32 X 3/16”

Split Helical Washer

for #8 Screw


3 RECOMMENDED TOOLS

Router or Saber Saw

Measuring Instrument (Ruler/Tape Measure)

Hammer Masking

Tape

Chisel

Fish Tape or Lead Wire

Center Punch

Wire Strippers/Cutter

Power Drill

Crimp Wire Connectors

1/8”, 5/32” and 3/4” Drill Bits

Crimp Tool

3/8” Diameter X 82° Countersink Bit

Multimeter

Phillips and Standard Screwdrivers


4 INSTALLATION
For a proper EPTL-SC install, all doors and frames must utilize a flush surface mount installation.
If the door/frame is pre-prepped by the manufacturer, then use the pre-fabricated mounting
features and the hardware provided to install the EPTL-SC as discussed in Section 4.3 or 4.4. If
the installation is a field retrofit, determine the door and frame construction, then proceed to
mark the door and frame in accordance with Section 4.1.

Flexible Shield

EPTL-SC Lead Cover (2)

Hardware Pack (2)

Flush Tab

Bracket (4)

Advertising