Operating Instructions

863 Valley View Road, Eighty Four, PA 15330 USA

Tel: 724-941-9701 Fax: 724-941-1369 e-mail: [email protected]

Replacing the Stack in an AirLite Pump

Removing the Stack

1. Unscrew the two screws retaining the belt clip and remove belt clip.

2. Remove the single retaining screw from the back of the pump case.

3. Press down gently on the inlet hose barb and slide

the stack and control board out of the bott om of
the case.

4. Use a small Allen wrench to loosen the setscrew

on each side of the pump housing.

Do not remove setscrews.