Enclosure Setup

Figure 7

2. Using four of the provided rack mounting screws, secure the

RX1600RAID enclosure to the rack;

do not overtighten the

screws (Figure 7).

C - Prepare the Drive Enclosure for Use

1. Remove a drive module from its packaging, and then pull out its

lever out until it stops

(Figure 8).

2. With its lever fully open, carefully slide the drive module into its

assigned slot (drive 1 in slot 1, etc.) in the enclosure until it stops,
and then secure it by pushing the lever in until it snaps closed.
(Figure 9).

3. Repeat steps 1 and 2 for each remaining drive module.

D - Connect the Drive Enclosure to the Sonnet RAID

Controller

This section describes the connection of the Fusion RX1600RAID
drive enclosure to the Sonnet RAID controller card.

1. Insert one end of each of the supplied data cables to the PRM

LINK mini-SAS ports on the enclosure;

verify the connectors are

plugged in securely (Figure 10).

5

screw

Figure 8

Pull lever out

until it stops

WARNING:

When handling computer products, take care to

prevent components from being damaged by static electricity;

avoid working in carpeted areas. Handle hard drives only by their
edges and avoid touching connector traces and component pins.

WARNING:

Before shipping a Fusion RX1600 storage system,

Sonnet formats and tests the included drives, and then

configures them as a RAID group. The individual drive modules are
then removed from the enclosure and labelled with numbers from
1 – 16, and then packaged. When setting up your Fusion storage
system, it is important that you install the drive modules into the
enclosure in numbered order, left-to-right
; if you don't do this, your
storage system’s performance will suffer.

WARNING:

When inserting drive modules into the enclosure,

do not force the levers closed. If a lever does not close easily,

remove and reinsert the module, and then push the lever in again.

Figure 9

Figure 10

mini-SAS

connector

Push lever in

until it snaps

closed

Push tray in

until it stops

Advertising