Harrington Hoists and Cranes Static/Dynamic Hoist Load Tester User Manual

Page 13

Advertising
background image

13

3. SEQUENCE OF OPERATIONS FOR DYNAMIC HOIST LOAD TESTER

IMPROPER test stand use could result in death or serious in
jury.
To avoid these hazards:
NEVER overload unit.
ALWAYS operate, inspect and maintain this test stand with
operator safety as a goal.
ALWAYS read owner's manual and safety instructions prior to
use.

3.1 The following is a suggested procedure for load testing an electric operated

hoist.

Step 1: If the hoist tester is mounted on casters,

insure that the caster pivot and rolling locks
are engaged.

Step 2: Always use the winch to lift heavy units into place.

Step 3: Using the hoist tester winch and hoist tester step, suspend a 1/4 to 5 ton hoist

from front top link (yellow, size 1) or 6 to 10 ton hoist from the rear top link
(orange, size 1 1/4).

Step 4: If the hoist is a Harrington ES series hoist, select the cord assembly with 5P

plugs on both ends. Next plug the one 5P plug into receptacle on the electri-
cal enclosure on the hoist test stand and the other 5P plug into the area
where the pendant plug is normally inserted at the lower portion of the electri-
cal enclosure of the hoist.