Table 5-2 periodic inspection intervals, Table 5-3 frequent inspection – Harrington Hoists and Cranes RHN - Rhino Wire Rope Hoist User Manual

Page 40

Advertising
background image

40

5.2.4

PERIODIC Inspection – visual inspection by a designated person with intervals per the following criteria:

Table 5-2

Periodic Inspection Intervals

Service

Hoist and Trolley Interval

Rope Inspection Interval

Normal

Service

Yearly

1) At Least monthly (per OSHA), AND

2) Determined by a qualified person and based

on such factors as expected rope life as
determined by experience on the particular or
similar installations; severity of environment;
percentage of capacity lifts; frequency rates
of operation; and exposure to shock loads.
Inspections need not be at equal calendar
intervals and should be more frequent as the
rope approaches the end of its useful life.
(per ANSI B30.16-2.4.1)

Heavy

Service

Semiannually

Severe

Service

Quarterly

Special or
Infrequent

Service

As recommended by a

qualified person before the

first such occurrence and

as directed by the

qualified person for any

subsequent occurrences.

5.3

Frequent Inspection

5.3.1

Inspections should be made on a FREQUENT basis in accordance with

Table 5-3

, “Frequent Inspection.”

Included in these FREQUENT Inspections are observations made during operation for any defects or damage
that might appear between Periodic Inspections. A designated person shall evaluate and resolve the results of
FREQUENT Inspections such that the hoist/trolley is maintained in safe working condition.

Table 5-3

Frequent Inspection

All functional operating mechanisms for maladjustment and unusual sounds.

Hoist and trolley in accordance with ANSI/ASME B30.16

Operation of all limit switches and associated components

Upper limit devices in accordance with ANSI/ASME B30.16

Hoist/trolley braking system for proper operation

Hooks and hook latches in accordance with ANSI/ASME B30.10

Hook latch operation

Wire rope in accordance with

Section 5.7

Wire rope reeving for compliance with

Section 3.6 and 6.4

Proper function of pendant controls.