4 home return – IAI America RCS2-SD5N User Manual

Page 62

Advertising
background image

8. Notes on Operation

-56-

8.4 Home Return

8.4.1 Home Return Operation

[1] As the motor turns, the rod returns to the negative side (actuator frame side) and contacts the mechanical

stopper.

[2] The rod reverses and turns by rotating angle D to find the encoder Z-phase.

The distance from the mechanical stopper to the position

where Z-phase is detected is as follows.

Lead

2.5 mm

5 mm, 10 mm

Distance

1.7 mm

2 mm

[3] The rod turns by rotating angle E from the position where the Z-phase was detected, and the attained offset

position (the offset conform to an applicable parameter value) is set as the home (points zero).

Z-phase detection sensor (mount side)

Mechanical stopper

Z-phase

Encoder disk (rotating side)

Z-phase detection sensor (mount side)

Rotating angle D

Z-phase detection sensor (mount side)

The offset from the position where the Z-phase is

detected to the home is 1.0 mm.

Rotating angle E

Advertising
This manual is related to the following products: