1. Specifications Check

33

[Moment and Transportable Weight of Flat Type (F5D)]

Shown in the table below is the allowable load on the tip calculated from Ma moment of each stroke.


Stroke

50

100

150

200

250

300

Distance from point of

action [m]

0.07

0.12

0.17

0.22

0.27

0.32

N

64.3

37.5

26.5

20.5

16.7

14.1

F5D Type

(kgf)

6.56

3.83

2.70

2.09

1.70

1.43