6.4.2 Heat Release Effect by Heat Sink Application

The graph below shows the temperature rise (maximum value) from the ambient temperature when
the unit is operated with 50% duty with 2 types of heat sinks applied on the attachment surface (top
surface).

Finger

Attachment Surface
(Upper side on side surface)

Attachment Surface
(Lower side on side surface)

Heat Sink

Reference data : Temperature Rise from Ambient Temperature (Maximum Value)

Ambient temperature at measurement : Approx. 25

qC

Heat Sink

Dimensions Material

Heat Sink

Attachment

Surface

(Upper side on

side surface)

Attachment

Surface

(Lower side on

side surface)

Finger

60

u 60 u 5

Aluminum

Anodized

Surface

Approx. 22

qC

Approx. 26

qC

Approx. 25

qC Approx.

36

qC

150

u 85 u 10

Aluminum

Polished

surface

Approx. 17

qC

Approx. 23

qC

Approx. 22

qC Approx.

34

qC


Note : Even if a heat sink is attached on the top of the unit, the temperature on the fingers

would not decrease much. To block heat from being conducted to the work part, use a
material with low heat conductivity such as polyacetal for the finger attachments. The
heat of the unit is conducted from the fingers to the work part via the finger
attachments.