[2] Load

Attachment

x There are M8 tapped holes prepared on the slider. Fix the work piece to be carried.
x The way to affix follows the installation of the main unit.
x There is a restriction on the moment and overhang load length when attaching a load to the

slider.

Type

Allowable

Load

Moment [N•m]

Overhang Load Length [L]

FS-11NM
FS-11NO

Fig. 1)

Single Slider

Ma: 2.9 (0.3)
Mb: 2.9 (0.3)
Mc: 4.5 (0.46)

Ma direction: 200 or less
Mb, Mc direction: 200 or less

FS-12NM
FS-12NO

Fig. 2)

Double Slider

(when sliders are

joined together)

Ma: 20.5 (2.1)
Mb: 18.6 (1.9)
Mc: 9.1 (0.93)

Ma direction: 500 or less
Mb, Mc direction: 500 or less

FS-11WM
FS-11WO

Fig. 1)

Single Slider

Ma: 4.4 (0.45)
Mb: 3.9 (0.4)
Mc: 5.8 (0.6)

Ma direction: 240 or less
Mb, Mc direction: 240 or less

FS-12WM
FS-12WO

Fig. 2)

Double Slider

(when sliders are

joined together)

Ma: 27.4 (2.8)
Mb: 25.4 (2.6)
Mc: 11.7 (1.2)

Ma direction: 600 or less
Mb, Mc direction: 600 or less

FS-11LM
FS-11LO
FS-11HM

Fig. 1)

Single Slider

Ma: 8.8 (0.9)
Mb: 7.8 (0.8)
Mc: 12.7 (1.3)

Ma direction: 300 or less
Mb, Mc direction: 300 or less

FS-12LM
FS-12LO
FS-12HM

Fig. 2)

Double Slider

(when sliders are

joined together)

Ma: 51.9 (5.3)
Mb: 47.0 (4.8)
Mc: 25.4 (2.6)

Ma direction: 750 or less
Mb, Mc direction: 750 or less

Single Slider (Fig. 1)

Double Slider (Fig. 2)

Allowable dynamic moment directions

The allowable dynamic moment is the value assuming 20,000km.
Use of the actuator above the moment specification could cause
a drop of the life of the guide.

Moment Directions

Overhang Load Length

Use of the actuator with an overhang
above the allowable range for each model
could cause vibration or delay in the
operation time. Make sure to use the
actuator in the allowable range.