14. Motor Replacement Procedures

77

(5) Removing the motor unit

[1] Loosen the coupling tightening bolt.

Caution: If the actuator is installed

vertically, exercise due caution

not to let the slider drop.

Hold the slider (work part) from

the outside to prevent it from

dropping, and then loosen the

coupling bolt.

(2) Remove the bolts used to secure the motor using an Allen wrench of 4 mm across flats, and pull out the

motor unit and coupling from the motor housing.

Body

Motor

Motor

Motor affixing bolt

Motor affixing bolt

Motor affixing bolt

Motor affixing bolt