2. Installation

38

2.3.4 Installation Surface

• For the platform to install the actuator, ensure the structure that possesses enough stiffness to

avoid vibration being generated.

• Install the actuator on a machined surface or other flat surface of equivalent accuracy. The

flatness of the installation surface must be 0.05 mm/m or less.

• Provide sufficient space to allow for maintenance work.

• The side and bottom surfaces of the actuator base provide datum surfaces used for alignment of

slider travel.

• If you require higher traveling accuracy, install the actuator using these datum surfaces.

Datum

surface

(Side of the base)

(Side of the base)

(Side of the base)

(Side of the base)

Small Type H8SS, H8SM, H8HS, H8HM

Flat Type L15SS, L15SM

Datum

surface

Datum

surface

Datum

surface

As shown above, each side surface of the base provides a datum surface used for alignment of

slider travel. If you require higher traveling accuracy, therefore, install the actuator with reference

to either side surface of the base.

When installing the actuator on the frame using the base datum surfaces, provide the necessary

machining by following the drawing below.

Model

Dimension A (mm)

Small Type

H8SS, H8SM, H8HS, H8HM

2 ~ 3.5 or less

Flat Type

L15SS, S15SM

2.5 ~ 4 or less

A

R0.3 or less