IAI America LSA-W21SS User Manual

Page 46

Advertising
background image

32


[4] Move the slider by hand over its full stroke and see the stainless sheet from above to confirm that

the specified dimensions on both sides of the stainless sheet are roughly uniform across the entire
length, as shown in the figure.
If not, the stainless sheet is skewed. Repeat the adjustment from step [1] to make sure the
stainless sheet extends straight.



















[5] Securely tighten the stainless-sheet retainer bolts that have only been loosely tightened, and then

install the inspection cover on the side of the slider cover.

[6] After the sheet retainer plate has been securely tightened, move the slider over its full stroke by

hand to check if the dimensions on both sides of the stainless sheet change significantly or if a
sound of slider contact is heard. If any problem is found, repeat the adjustment from step [1].


Warning:
 This actuator uses high-performance rare-earth permanent magnets. Accordingly, anyone

who is using a pacemaker or other medical device should not perform this work.

 Do not bring a watch, mobile phone or any other electronic device susceptible to the

magnetic field closer to the actuator.

 Wear gloves and exercise caution not to cut your hand by the stainless sheet during the

procedure.

 Pay due attention not to let the permanent magnets attract iron powder or other magnetic

objects during the procedure.


Caution:
Always use IAI’s genuine stainless sheet.
If IAI’s genuine stainless sheet is not used, actuator breakdown may occur.


These dimensions on both sides must be roughly

uniform.