31

6. Inspection/Maintenance

(4) Remove the two cap screws (M4 x 8) [2] on the cap, and remove the cap.
(5) Loosen the cap screw (M5 x 15) [3] on the stopper, and remove the stopper, gasket and bearing case

in this order.

(6) Remove the four cap screws (M3 x 15) [4] affixing the bellows, and remove the bellows.
(7) Lift the cover and remove upward.

z If the cover is removed, absolute reset must be performed again for the rotational axis (arm 2) and

vertical axis. (See 6.4, “Absolute Reset Procedure.”)

z Do not cause the wires to be pulled with excessive force when lifting the panel.

Stopper

[2] CAP 2 - M4 x 8

Cap

[4] CAP 4 - M3 x 15

[3] Loosen CAP M5 x 15

Gasket

Bearing case

Lift the cover and
remove upward.