IAI America XSEL-S User Manual

Page 23

Advertising
background image

3. XSEL-R/S/RX/SX/RXD/SXD

17

[7] Number of I/O Port Setting

Set the number of ports to be used for I/O Parameters No.14 to 15.

Set a number that is a multiple of 8.

No.

Parameter name

Default

(reference)

Input Range

Unit

Remarks

14

Network I/F Module 1

Number of Remote Input

Ports

0

0 to 256

- Multiples of 8

15

Network I/F Module 1

Number of Remote Output

Ports

0

0 to 256

- Multiples of 8

[8] I/O Port Top Number Setting

Set the top port number of the port range used in I/O Parameters No.16 to 17.

Note The port numbers assigned here are the starting input and output port numbers.

Add the number of ports assigned in parameters 231 and 232 to determine the I/O

range.

The values entered into these parameters must be evenly divisible by 8 (EX: 300)

No.

Parameter name

Default

(reference)

Input Range

Unit

Remarks

16

Network I/F Module 1

Fix-Allocated Input Port Start

No.

-1

-1 to 3999

-

0+(Multiples of 8)(0 to 299)

1000+(Multiples of 8)(1000 to 3999)

(Unavailable when it is negative figure)

17

Network I/F Module 1

Fix-Allocated Output Port

Start No.

-1

-1 to 6999

-

300+(Multiples of 8)(300 to 599)

4000+(Multiples of 8)(4000 to 6999)

(Unavailable when it is negative figure)

[9] EtherNet/IP Board Use Setting

Set “1” (Monitoring: use EtherNet board) to I/O Parameter No.18.

No.

Parameter name

Default

(reference)

Input Range

Unit

Remarks

18 Network I/F Module 1

Error Monitor

1

0 to 5

- 0: No Monitoring

1: Monitoring

[10] Time Setting to Wait for EtherNet/IP Communication Establishment

Set the maximum allowable time for the establishment of EtherNet/IP communication at the

startup in bits 16 to 23 of I/O Parameter No.120. Change this setting when XSEL starts faster

than the master unit, which results in a generation of “D5D” or “A6B”.

No.

Parameter name

Default

(reference)

Input Range

Unit

Remarks

120 Network Attribute 1

640001H

0H to

FFFFFFFFH

100

msec

Bit 16 to 23: Value of Link Timeout at initializing

(Example) The initial value 640001H is

Bit 16 to 23 = 64H = 100

(in 100ms unit)

100×100ms = 10sec

It waits for 10sec at maximum

from the startup for the

communication establishment.

[11] Data Retaining Setting at EtherNet/IP Communication Error

Set whether to clear the input port data with 0 or to retain when an error is generated in bits 28

to 31 of I/O Parameter No.120.

No.

Parameter name

Default

(reference)

Input Range

Unit

Remarks

120 Network Attribute 1

640001H

0H to

FFFFFFFFH

Bit 28 to 31: Network I/F Module 1

Input port data select for link

error

(0: Clear, 1: Hold)

Advertising