[7] Number of I/O Port Setting
Set the number of ports to be used for I/O Parameters No.14 to 15.
Set a number that is a multiple of 8.
No.
Parameter name
Default
(reference)
Input Range
Unit
Remarks
14
Network I/F Module 1
Number of Remote Input
Ports
0
0 to 256
- Multiples of 8
15
Network I/F Module 1
Number of Remote Output
Ports
0
0 to 256
- Multiples of 8
[8] I/O Port Top Number Setting
Set the top port number of the port range used in I/O Parameters No.16 to 17.
Note The port numbers assigned here are the starting input and output port numbers.
Add the number of ports assigned in parameters 231 and 232 to determine the I/O
range.
The values entered into these parameters must be evenly divisible by 8 (EX: 300)
No.
Parameter name
Default
(reference)
Input Range
Unit
Remarks
16
Network I/F Module 1
Fix-Allocated Input Port Start
No.
-1
-1 to 3999
-
0+(Multiples of 8)(0 to 299)
1000+(Multiples of 8)(1000 to 3999)
(Unavailable when it is negative figure)
17
Network I/F Module 1
Fix-Allocated Output Port
Start No.
-1
-1 to 6999
-
300+(Multiples of 8)(300 to 599)
4000+(Multiples of 8)(4000 to 6999)
(Unavailable when it is negative figure)
[9] EtherNet/IP Board Use Setting
Set “1” (Monitoring: use EtherNet board) to I/O Parameter No.18.
No.
Parameter name
Default
(reference)
Input Range
Unit
Remarks
18 Network I/F Module 1
Error Monitor
1
0 to 5
- 0: No Monitoring
1: Monitoring
[10] Time Setting to Wait for EtherNet/IP Communication Establishment
Set the maximum allowable time for the establishment of EtherNet/IP communication at the
startup in bits 16 to 23 of I/O Parameter No.120. Change this setting when XSEL starts faster
than the master unit, which results in a generation of “D5D” or “A6B”.
No.
Parameter name
Default
(reference)
Input Range
Unit
Remarks
120 Network Attribute 1
640001H
0H to
FFFFFFFFH
100
msec
Bit 16 to 23: Value of Link Timeout at initializing
(Example) The initial value 640001H is
Bit 16 to 23 = 64H = 100
(in 100ms unit)
100×100ms = 10sec
It waits for 10sec at maximum
from the startup for the
communication establishment.
[11] Data Retaining Setting at EtherNet/IP Communication Error
Set whether to clear the input port data with 0 or to retain when an error is generated in bits 28
to 31 of I/O Parameter No.120.
No.
Parameter name
Default
(reference)
Input Range
Unit
Remarks
120 Network Attribute 1
640001H
0H to
FFFFFFFFH
Bit 28 to 31: Network I/F Module 1
Input port data select for link
error
(0: Clear, 1: Hold)