93

8.3. Master PLC address assignment


The basic concept of address assignment (memory map) for the CC-Link master PLC has been explained in
5.2. This section explains a case when the gateway unit is a remote station. If the gateway unit is a remote
device station (remote station which handles bit information and word information), the number of exclusive
stations depends on the operation mode.

Input and output region

Operation mode

Remote I/O

Remote

register

Number of exclusive

stations

Number of

controlled axes

Position data limit designation

8 word

16 word

4

14

Position No. designation

8 word

16 word

4

14

Normal position data designation

8 word

16 word

4

7

Push operation data designation

8 word

16 word

4

3

Small

10 word

24 word

* Depends on setting

16 max.

Middle

20 word

48 word

* Depends on setting

16 max.

Simple direct
value/Position No.
designation

Large

24 word

64 word

* Depends on setting

16 max.


* Number of links per one CC-Link remote station is 32 points (two words) for remote input and output, and

four points (four words) respectively for remote register, then a maximum 64 stations per one system can be
linked.
Number of links per one station can be expanded by the expanded cyclic setting.