IAI America PS-24 User Manual

Page 21

Advertising
background image

17

Both methods A (standard) and B below are available as a mounting method, however, the
characteristics for the output current relevant to the temperature will differ for each way. Use
within the range of its characteristics for each method.

Method A

(Standard)

Method B

Mounting

Surface

Output Current

(%)

110

100

90

80

70

60

50

40

30

20

10

0

Ambient Temp. (

oC)

A (Standard)
B

0

10

20

30

40

50

60

Note :

The main housing of the product gets so hot that it sometimes gives you a burn as it works
as a heat sink.

Do not touch while the power is ON, or even after the power is OFF until the heat calms

down.

Advertising