For emitter:

Function

Status

Meaning

LED

DIGIT

TEST
(green ON)

Light curtain being tested. OSSD status on
the receiver must be OFF

Normal operation

Emission
(green ON yellow
ON)

Light curtain in normal operating condition

Function

Type

Check and repair

LED

DIGIT

Internal error

(green ON)

Switch OFF and switch ON the power
supply circuit. If the failure continues
contact DATASENSOR

Optical error

(green ON)

Switch OFF and switch ON the power
supply circuit. If the failure continues
contact DATASENSOR

Error status

No power supply

(LEDs OFF)

Check connections and input voltage
correct value. If the failure continues
contact DATASENSOR
























6

Receiver

Emitter


Signals are clearly identified through symbols allowing immediate reading, independent of bars directions.
A short description of the signalling LEDs is necessary to avoid misunderstandings.

Two yellow LEDs (

LAST,

SYNC) on SG4-B receiver, facilitate the alignment procedure.

Correct alignment procedure

The light curtain alignment can be effected only after having completed the mechanical installation and the
electrical connections. The following procedure has to be followed:

NOTE: SG4-B is equipped with a system which informs the user on the alignment obtained.
The alignment function can be activated when powering the device, by keeping the normally open
RESET/RESTART contact closed for at least 0.5 seconds.

Display

LED

NORMAL

OP.

LED

SAFE

(BREAK)

LED

yellow

SYNC

LED

yellow

LAST

Condition

Alignment

Status

ON

Sync NOK
Last NOK

OFF

ON

Sync OK
Last NOK

OFF ON

OFF OFF

Sync OK
Last OK

Middle optics NOK

NO align.

ON OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

0 and 25%

MINIMUM

align.

ON OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

25 and 50%

ON

OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

50 and 75%

ON

OFF

OFF

OFF

Each beam is over the min.
operating threshold and the

number of beam over the

threshold is included between

75 and 100%

MAXIMUM

align.






3

Last optics (LAST)

First optics (SYNC) =
synchronisation optics

NORMAL

OP.

SAFE

(BREAK)

LAST

SYNC

NORMAL

OP.

ON

Advertising