5

CAUTION FOR RACK ASSEMBLY

1. Ensure that power is switched off before installation and before any wiring is connected to the equipment.
2. Site the equipment in well ventilated places and avoid places of high humidity.
3. Whenever possible, fit Inter-M MIC model CM-916. If a Phantom powered MIC is to be used, we recommend

that it operates on +5V DC.

4. Please observe wiring polarity when connecting DC Power to the equipment.
5. Before connecting to the RM-916 LINE OUT terminals, check and match the incoming wiring for HOT, COLD

& GND potential.

CONNECTOR SECTION FUNCTIONS

1. LINE OUTPUT TERMINALS

Connect the line output terminals to the REMOTE INPUT JACK of the Inter-M EMERGENCY PANEL EP-
9216.

2. AUX INPUT TERMINALS

Connect the line output of a Cassette Deck, Tuner or CD player to these terminals. The input sensitivity of the
AUX input is –20dB.

3. 24V DC POWER INPUT TERMINALS

Connect the 24V DC OUTPUT of the Inter-M POWER DISTRIBUTOR PD-9359 to these terminals.

4. SPEAKER CONTROL & COM TERMINALS

Connect these speaker control line terminals to the REMOTE 1 or REMOTE 2 inputs of the Inter-M PX-9116
MATRIX unit.

POWER

AUX

MIN

MAX

MIC

MIN

MAX

CHIME

MIN

MAX

MIC INPUT

15

8

7

6

5

4

3

2

1

10 11 12 13 14

9

16

RM

COM

G

+

H

G

C

H

SPEAKER CONTROL

LINE OUT

DC 24V

IN

AUX

IN

Advertising