Eap security & server certificates - overview – AMX Modero ViewPoint MVP-8400 User Manual

Page 123

Advertising
background image

Setup Pages

109

MVP Modero ViewPoint Touch Panels

EAP Security & Server Certificates - Overview

The following EAP types all support a server certificate:



EAP-PEAP



EAP-TTLS



EAP-TLS

All three of these certificate-using security methods are documented in the following sections. EAP
Authentication goes a step beyond just encrypting data transfers, but also requires that a set of
credentials be validated before the client (panel) is allowed to connect to the rest of the network
(FIG. 86). Below is a description of this process. It is important to note that there is no user intervention
necessary during this process. It proceeds automatically based on the configuration parameters entered
into the panel.

A server certificate file uses a certificate that is installed in a panel so that the RADIUS server can be
validated before the panel tries to connect to it. The field name associated with this file is Certificate
Authority
.

Batteries Page (Cont.)

Battery Status:

• The Combined Charge Status bargraph indicates the combined power

charge available from batteries installed in the panel.

• The Battery One Charge Status bargraph indicates the power charge

available on the Slot 1 battery (in the panel).

• The Battery Two Charge Status bargraph indicates the power charge

available on the Slot 2 battery (in the panel).

• The Battery Dock 1 Charge Status bargraph indicates the power charge

available on the docking station’s battery #1.

• The Battery Dock 2 Charge Status bargraph indicates the power charge

available on the docking station’s battery #2.

Note: If no batteries are being charged within the docking station’s battery
compartments, or the MVP is not connected to a docking station; both Battery
Dock Charge Status fields are left blank.

• The Docking Station Version field indicates the firmware version currently

installed on the docking station.

• The Battery Level Port field indicates the port being used to report charge

status levels back to the NetLinx Master (set in TPDesign4).

• The Battery Level field indicates the level being used to report status levels

back to the NetLinx Master (set in TPDesign4).

FIG. 86

EAP security method in process

LAN

Client - Panel

(supplicant)

802.1x

(EAP over Wireless)

Authenticator

(Wireless Access Point)

Authentication Server

(RADIUS Server)