Miscellaneous mvp strings back to the master, Undock <master, Dock – AMX Modero ViewPoint MVP-8400 User Manual

Page 155: Undock <master> dock ^txt ^uni ^vtp

Advertising
background image

Programming

141

MVP-7500/8400 Modero Viewpoint Wireless Touch Panels

Miscellaneous MVP Strings back to the Master

The following two strings are sent by the MVP panel back to the communicating Master:

"^" Button Commands (Cont.)

^TXT

Assign a text
string to those
buttons with a
defined address
range.

Sets Non-Unicode text.

Syntax:

"'^TXT-<vt addr range>,<button states range>,<new text>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

new text = 1 - 50 ASCII characters.

Example:

SEND_COMMAND Panel,"'^TXT-500.504&510.515,1&2,Test Only'"

Sets the On and Off state text for buttons with the variable text ranges of
500-504 & 510-515.

^UNI

Set Unicode text.

For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as
ASCII-HEX nibbles.

Syntax:

"'^UNI-<vt addr range>,<button states range>,<unicode text>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

unicode text = Unicode HEX value.

Example:

SEND_COMMAND Panel,"'^UNI-500,1,0041'"

Sets the button’s unicode character to ’A’.
Note: To send the variable text ’A’ in unicode to all states of the variable text
button 1, (for which the character code is 0041 Hex), send the following command:

SEND_COMMAND TP,"'^UNI-1,0,0041'"

Note: Unicode is always represented in a HEX value. TPD4 generates (through the Text
Enter Box dialog) unicode HEX values. Refer to the TPDesign4 Instruction Manual for
more information.

^VTP

Simulates a
touch/release/
pulse at the given
coordinate.

Syntax:

^VTP-<0=Release, 1=Press, 2=Pulse>,<x>,<y>

MVP Strings to Master

undock <master>

This is sent to the target Master when the MVP is undocked.

• If the panel has no information within the User Access Passwords list, ’none’ is sent as

a user.

• If the undock button on the Protected Setup page is used, ’setup’ is sent as a user.

• This string can be disabled from within the firmware setup pages.

dock

This is sent to the target Master when the MVP is docked.

• This string can be disabled from within the firmware setup pages.