Set up instructions, Must read before use, Step 1 – IPA Tools 9040 Fuel Tank Sweeper User Manual

Page 5: Step 2, Step 3, Optional accessories

Advertising
background image

5

MUST READ BEFORE USE

This diaphragm pump is meant for use with liquids only. DO NOT suck

up leaves, gravel and other solids. Doing so will void the warranty. Manu-

facturer suggests the use of a screen filter on the intake side.

(Reference part # 9040-TFIL)

SET UP INSTRUCTIONS:

STEP 1

Take the male quick disconnect from one end of the hose and connect it to the female

quick disconnect for either input or output of the pump. Repeat for other hose.

STEP 2

Hook up shop air to the small ball valve on the front of the pump.

Max air pressure is 100PSI.

STEP 3

Open ball valve and turn on pump.

OPTIONAL ACCESSORIES:

8 FT. EXTENSION HOSE #9040-8EXT
1.
To connect the 8ft. extension hose between the sweeper

®

and

the hose that you want to extend, take the male quick disconnect

of the 8ft. extension hose and put it into the desired female port

of the Sweeper.

2. Take the female end of the 8 ft. extension hose and attach it to

the male end of the hose you are extending.

3. To couple the male and female quick disconnects together, put

the male quick disconnect into the female quick disconnect.

4. Pull the levers on the side of the female end all the way down towards itself tight

against the side. Be sure to insert the cotter pins through the hole to lock the levers

in place.

NOTE: During the pump operation, excessive vibration can loosen the coupling

locking handles. Be certain to use the locking cotter pins.
5. To maintain the clear appearance of the hose after use, it is good practice to gravity

drain all fluid from the hose. Then using warm soapy water, flush until clean and air

drain and dry afterwards.

NOTE: Depending upon what contaminates are present when using the hose and

how well it is cleaned afterwards determines how long the hose remains clear.

The hose is warranted to be free from manufacturer’s defects for one year.

Digital Flow Meter

9040-FLOM

T-Filter for

large particles

9040-TFIL

#9040-8EXT

8 Ft. Extension

Hose

Advertising