Capacitor Cavity

1. The capacitor cavity adjoins the limit switch cavity and provides a wiring access hole. Various

wiring will need to be carefully routed through this cavity to the access hole on the other side.
Keep this in mind when attaching the electrical leads to and from the limit switches,
potentiometer, motor, and capacitor.

2. Using the wiring diagram in Section 4-1, and this manual, connect the various wires and pass

the leads through the capacitor cavity and out the access hole.

3. Insert the capacitor with the terminals upward toward the cover. Exercise caution when

handling the capacitor. Touching the terminals may result in electrical shock. To safely
discharge the stored energy in the capacitor consult an electrician.

4. Double-check all electrical connections before attaching the gasket (45) and the cover (46)

with screws (47).