SIVFR Signal Isolator and Run/Fault Relay (Part No 9597)

SIVFR Signal Isolator and Run/Fault Relay (Part No 9597)

SIVFR Signal Isolator and Run/Fault Relay (Part No 9597)

SIVFR Signal Isolator and Run/Fault Relay (Part No 9597)

Supplemental Information for Installation and Operation Manual Part No. A40264

Supplemental Information for Installation and Operation Manual Part No. A40264

Supplemental Information for Installation and Operation Manual Part No. A40264

Supplemental Information for Installation and Operation Manual Part No. A40264

(A42132) – Rev. B01 – 9/18/2006 – Z3017B01

Page 1 of 8

The SIVFR is Designed to be Used with the Following KBVF 2G Series Drives

1

(for KBVF 2G Software Revision Codes 1.47 or Higher Only)

2

KBVF-21D (Part No. 9581), KBVF-22D (Part No. 9572),

KBVF-13 (Part No. 9957), KBVF-23 (Part No. 9958), KBVF-23D (Part No. 9959),
KBVF-14 (Part No. 9977), KBVF-24 (Part No. 9978), KBVF-24D (Part No. 9979),
KBVF-26D (Part No. 9496), KBVF-27 (Part No. 9591), KBVF-29 (Part No. 9593).

Notes: 1. Models KBVF-45 (Part No. 9590) and KBVF-48 (Part No. 9592) contain a built-in SIVFR. 2. The software
revision code is printed on the right side of the 2.25” X ⅜” silver “WARNING: HIGH VOLTAGE!” label, which is located on
the top of the KBVF heat sink. The revision code is given in the format “XX/1.47”.

Kit Includes

Kit Includes

Kit Includes

Kit Includes

SIVFR Signal Isolator and Run/Fault Relay PC Board, Interconnecting Ribbon Cable,

Enclosure Base, Enclosure Cover, Breakaway Finger-Safe Panel, and Mounting Screws.

IMPORTANT:

IMPORTANT:

IMPORTANT:

IMPORTANT: The following information and instructions are to be used as a supplement to the SIVF Installation and Operation Manual
(Part No A40264). The SIVF and KBVF manuals must be read and understood before attempting to operate this control. For further
assistance, contact our Sales Department at 954-346-4900 or Toll Free at 800-221-6570 (outside Florida).

The KBVF and SIVFR have been changed to second generation versions (2G). The General Performance Specifications have not changed.
The SIVFR contains a Run/Fault Relay which can be used to turn on or off equipment or to signal a warning if the drive is put into the Stop
Mode or if a fault has occurred, as described in Section 4, on pages 7 and 8.

WARNING! High voltage is present while LEDs are illuminated. Before wiring the SIVFR to the KBVF, disconnect all power to the

KBVF and wait until the "PWR" and "ST" LEDs are no longer illuminated.

Notes: 1. Do not mount the SIVFR onto the KBVF until the ribbon cable is properly routed and installed. See Sections 1.1 – 1.4, on pages
2 – 4. 2. Do not install the enclosure cover until the SIVFR is mounted onto the KBVF and all wiring on the SIVFR is complete. See Sections
1.5 and 1.6, on pages 4 and 5. 3. For added protection, a break-away finger-safe panel is provided to close the exposed area of the SIVFR
between Terminal Blocks TB1 and TB2. See Section 5, on page 8. 4. Jumper J5 is factory set to the “NDBM” position for operation without
the optional Dynamic Brake Module installed with the KBVF. If using a Dynamic Brake Module, set Jumper J5 to the “DBM” position. See
Figure 1.

Figure 1

SIVFR Layout