KB Electronics KBRC-240D User Manual

Page 6

Advertising
background image

6

Potentiometer rotation or input signal. In the Non-Linear Torque mode (NL), the torque is var-
ied by the Main Speed Potentiometer or input signal, and remains constant throughout the
motor’s entire speed range. In addition, Regenerate-to-Stop (RTS) or Coast-to-Stop (CTS)
stop modes are also provided.

Standard front panel features of the KBRC-240D include diagnostic LEDs (for Power On,
Stop and Overload), a Start/Stop Switch and a Main Speed Potentiometer. Other features
include Barrier Terminal Blocks (facilitates wiring of the AC line, motor armature and field,
tach-generator and run relay), adjustable trimpots (OFFSET, FACC, RACC, MAX, FWDCL,
REVCL, IR, RESP, DB and TCL), selectable jumpers (AC line voltage, motor voltage or tach
feedback, motor current, analog input voltage, control mode, torque mode, current limit
mode, stopping mode, run relay output contacts and enable) and PC Board mounted LEDs
(Power On, Overload, Forward Enable and Reverse Enable).

Optional accessories for the KBRC-240D include a Forward-Stop-Reverse Switch,
Auto/Manual Switch, Power On/Off Switch and a Signal Isolator. Quick-connect terminals are
provided for easy installation of all accessories. See Section X, on page 22.

TABLE 1 – GENERAL PERFORMANCE SPECIFICATIONS

TABLE 2 – ELECTRICAL RATINGS

Notes: 1. Step-down operation: Motor may have reduced brush life. Consult motor manufacturer.

2. Requires an isolated signal. If a non-isolated signal is used, install the Signal Isolator SIRC (P/N 8842).

Note:

1. Step-down operation: Motor may have reduced brush life. Consult motor manufacturer.

Parameter

Specification

Factory

Setting

AC Line Input Voltage (Volts AC, ±10%, 50/60 Hz)

115 and 208/230

230

Armature Voltage Range at 115 Volts AC Line (Volts DC)

0 – ±90

Armature Voltage Range at 208/230 Volts AC Line (Volts DC)

0 – ±90

1

, 0 – ±180

0 – ±180

Field Voltage at 115 Volts AC Line (Volts DC)

100/50

Field Voltage at 208/230 Volts AC Line (Volts DC)

200/100

Signal Following Input (Non-Isolated

2

) Range (Volts DC)

0 – ±10, 0 – ±15

0 – ±15

Signal Following Linearity (% Base Speed)

1

Line Regulation (% Base Speed)

±0.5

Armature Feedback Load Regulation (% Base Speed)

±1

Tach-Generator Feedback Load Regulation (% Set Speed)

±1

Maximum Load Capacity (% for 2 Minutes)

150

Current Ranges (Amps DC)

1.7, 2.5, 5, 7.5, 10

10

Speed Range (Ratio)

50:1

Operating Temperature Range (°C)

0 – 45

Offset Trimpot (OFFSET) Range (% Base Speed)

0 – ±10

0

Reverse Acceleration Trimpot (RACC) Range (Seconds)

0.2 – 15

1

Forward Acceleration Trimpot (FACC) Range (Seconds)

0.2 – 15

1

Maximum Speed Trimpot (MAX) Range (% Base Speed)

70 – 110

100

Forward Current Limit Trimpot (FWDCL) Range (% Range Setting)

0 – 200

150

Reverse Current Limit Trimpot (REVCL) Range (% Range Setting)

0 – 200

150

IR Compensation Trimpot (IR) Range at 90 Volts DC Output (Volts DC at Full Load)

0 – 15

IR Compensation Trimpot (IR) Range at 180 Volts DC Output (Volts DC at Full Load)

0 – 30

10

Deadband Trimpot (DB) Range (% Base Speed)

0 – ±3

0.5

Timed Current Limit Trimpot (TCL) Range (Seconds)

0 – 15

5

AC Line Input Voltage

(±10%, 50/60 Hz)

(Single Phase Volts AC)

Maximum AC Line

Input Current

(Amps AC)

Nominal Output

Voltage

(Volts DC)

Maximum Output

Load Current

(Amps DC)

Maximum

Horsepower Rating

HP, (kW)

115

15

0 – ±90

11

1, (0.75)

208/230

15

0 – ±180

11

2, (1.5)

208/230

15

0 – ±90

1

11

1, (0.75)

Advertising