King Electric CDP-2 User Manual

Cdp-2, Snow sensor control/display panel, Automated systems engineering

Advertising
background image

Home Automation Interface

The CDP-2 also includes an input for optional home automation control. This interface provides the

capability to trigger the system through telephone or computer control.
Closure of the Trigger and Enable inputs will start one snow melting
cycle, just as though the MANUAL ON button was pressed. Once the
cycle is complete the sensor will revert to AUTOMATIC mode.

The Enable input is an optional connection point for a second “safety”
contact set. If used, both contact sets must close to trigger the snow
melt system. This can help eliminate inadvertent cycling of the
system. If only one contact set is available the user may install a
jumper wire across terminals 3 & 4. The user may also connect a
simple toggle switch across the Enable input to allow manual enabling
and disabling of the home automation interface.

LIMITED WARRANTY

The CDP-2 is warranted against defects in workmanship and materials for two years from date of sale.
This warranty does not apply to damage resulting from accident, misuse, or alteration nor where
connected voltage to the attached snow sensor is more than 5% above the configured operating voltage,
nor to equipment improperly installed or wired or maintained in violation of this Owner’s Manual. No
other written or oral warranty applies. No employee, agent, dealer or other person is authorized to give
any warranties on behalf of ASE.

The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of
the product for repairs. Within the limitations of this warranty, inoperative units should be returned,
freight prepaid, to ASE, and we will repair or replace, at our option, at no charge to you with return freight
paid by ASE. It is agreed that such repair or replacement is the exclusive remedy available from ASE
and that ASE IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND
CONSEQUENTIAL DAMAGE. Some states do not allow the exclusion or limitation of incidental or
consequential damages so the above exclusion may not apply to you. The warranty gives you specific
legal rights, and you may also have other rights which vary from state to state.

AUTOMATED SYSTEMS ENGINEERING, INC.
2519 E SAINT VRAIN ST
COLORADO SPRINGS, COLORADO 80909
PHONE: 719-599-7477 FAX: 719-599-7482

Visit us on the Internet at: www.goase.com




ASE now offers interconnect cable approved for CDP-2 installation.

Ask your distributor about CS-50 (50 foot), CS-100 (100 foot), and CS-200 (200 foot) rolls of

22 AWG, stranded, shielded, 6 conductor cable with matching color code,

a spare lead, and a UL 300V rating.


4

CAUTION: Read all instructions carefully before installation.

Save this Installation Manual for future reference.

CDP-2

SNOW SENSOR

CONTROL/DISPLAY PANEL

INSTALLATION MANUAL

Manufactured By

AUTOMATED
SYSTEMS
ENGINEERING

2519 East Saint Vrain St Colorado Springs, Colorado 80909

TRIGGER

ENABLE

Advertising