Installation instructions, Save these instructions, As-fs gw – King Electric Model HT User Manual

Page 3

Advertising
background image

backside

2½"

13¼"

left side

5"

right side

½" electrical

knockout

" hole size

12 "

3 "

20 "

3 5/16"

(18¼" without grille)

3 "
without
grille

12 "

18 "

interior

18 " without grille

water feed

wiring
junction box

mounting
slots

mounting
slots

LEGEND

SC - switch common

SC-R - switch common 2/3 & 3/4

SH - switch high speed

SL - switch low speed

MH - motor high lead

ML - motor low lead

M - motor common

Q1 - aqua switch

Q2 - aqua switch

L1Q - power lead with aquastat

L1XQ - power lead without

aquastat

N - neutral lead

HT wiring:ai : 1/10

Neutral

White

White

Fan Switch

Hi / Low

Black

Red

White

Black

High

Speed

Red

Low

Speed

Aquastat

120 Volt

with

Aquastat

120 Volt

without

Aquastat

Black

Power

Black

Option

N

SC

SC-R

L1Q

SH

MH

ML

Q1

Q2

SL

L1 XQ

M

Blue

Optional

Motor Speed Resistor

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

KING ELECTRICAL MFG. COMPANY · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH: 206.762.0400 · FAX: 206.763.7738 · www.king-electric.com

HT.indd : 1/10

Specifications:
HT Model Number Legend
HT 8 12 5/7 AS-FS GW

H

8

12

5

/

7

H Series Hot Water

Voltage 120

5000 BTU heat output @ 140 Degree water input
7000 BTU heat output @ 160 Degree water input

Inlet water temperature range: 100 to 200 Degree F
Air Delivery: 30 to 50 CFM
CFM High Speed: 50

Motor Amps .48 @ 120 Volt

CFM Low Speed: 30

Motor Amps .40 @ 120 Volt

Power Supply: 110 to 125 Volt AC 50/60 cycle

Electrical Circuit Sizing

Maximum 15 Amps

circuit breaker or fusing

One year warranty from date of installation

Number of copper tubes in coil

AS-FS

GW

Grille White or Black color

Aqua Stat / Fan Switch

T

T Toe Space

Advertising