background image

30'

6'-0"

1

INSTALL IN 30" DIA. X 78" DEEP

3

2

5

GROUND LINE

CONCRETE FOOTING

ANTI-ROTATIONAL

PLATES

NOTE: SPECIFICATIONS ARE SUBJECT TO CHANGE

8'

INSTALLATION INSTRUCTIONS

1. DIG FOOTING AT PROPER LOCATION

30" DIA. X 78" DEEP

2. PLACE BASE POST (1) INTO FOOTING

AND SUPPORT IN A PLUMB CONDITION

WITH THE OUTSIDE EDGE OF PIPE TANGENT

TO THE OUTSIDE OF THE FOUL LINE.

TOP OF POST TO BE 9'-0" ABOVE FIN. GRADE

(NOT TOP OF SLEEVE)

3. INSTALL THE PANELS IN THE TOP POST (2)

USING THE CLIPS (5) AND BOLTS (4) . TIGHTEN

4. AFTER CONCRETE HAS SET 16 hrs. PLACE

THE TOP POST (2) IN BASE POST USING A

LIFTING DEVICE (CRANE) ROTATE THE POST

SO THAT THE PANELS ARE TO THE INSIDE

OF THE FIELD

5. REPEAT FOR OTHER FOUL LINE

DO NOT SCALE DRAWING

STEELCRAFT PRODUCTS

P.O. Box 90365 - Pasadena, CA 91109

DATE: 1/17/06

DRAWN BY: AFS

MODEL

PHN 626-798-7401 FAX 626-798-1482

FLP-30

FOUL POLE

SURFACE MOUNT DETAIL

FLP-30SM

SURFACE MOUNTED

AVAILABLE

15" X 15" X 1"

STEEL PLATE

ITEM QTY. PART

NO

DESCRIPTION

1

1

F04FP03X

5-9/16" OD Sch 40 POST

3

2

F02FP000

SCREEN

4

18

P01FP000

BOLT/WASH/NUT

5

2

F02FP001

CLIPS