3.

MOUNTING THE REMOTE KEYPAD

The diagram below illustrates how to mount the remote keypad to a panel. Use
the template in Section 2 to mark the location of the mounting holes on the
panel.

PANEL

REMOTE

KEYPAD

GASKET

MOUNTING

SCREWS

2.

SM REMOTE KEYPAD TEMPLATE

Hold this page against the panel where the remote keypad is to be mounted,
and use a center punch to mark the location of the holes. The dotted line is the
outline of the remote keypad.

174194.00

- SM SERIES

REMOTE KEYPAD

INSTRUCTIONS

The SM Series Remote Keypad option allows the SM Series drive to be
programmed and controlled from up to 8 feet away (typically from the
front of the enclosure that houses the SM drive). When properly mounted,
the remote keypad is rated up to NEMA 4X.

In addition to the functions available on the front of the SM drive, the
remote keypad has Start/Stop and Forward/Reverse functions.

NOTE: The Remote Keypad option will only work with SM drives that
have parameter version “320” or higher. The parameter version appears
momentarily on the drive display when it is powered up, and also appears
on a sticker on the drive’s heatsink.

1.

PARTS LIST

The SM Remote Keypad kit includes the following parts:

(1)

Remote Keypad

(1)

Gasket

(2)

Self-tapping Mounting Screws

(1)

Instruction Sheet

(1)

Eight foot cable

NOTE: The supplied cable is unshielded and can only be used in low-noise
environments. In high-noise environments, use Belden 9842, Carol C4842, or
equivalent (24 gage minimum) wire only. The maximum cable length that can
be used is 8 feet.

1/8” hole

1/8” hole

1.57”

1.32”

1.38” to 1.5”

hole

3.38”

2.19”

UP

Max Depth = 0.72”

4.

WIRING CONNECTIONS

NOTE: The supplied cable is unshielded and can only be used in low-noise
environments. In high-noise environments, use Belden 9842, Carol C4842, or
equivalent (24 gage minimum) wire only. The maximum cable length that can
be used is 8 feet.

WARNING!

Improper wiring may result in damage to the Remote Keypad. Keep the
remote keypad cable away from power wiring.

The Belden and Carol cables specified consist of two twisted pairs. Make
sure one twisted pair is used for connections to 13B and 13E, and the
other is used for connections to 11 and 2. Do not mix connections
between twisted pairs.

REMOTE KEYPAD

(BACK VIEW)

13B

13E

11

2

UP

1

2

5

6

11

13A 13B

25

13E

Cable included with kit
does not have a shield

WARNING!

If OEM mode is selected (using Parameter 48), and if the OEM Default
settings for Parameters 11, 12, and 14 are not “13”, “21”, and “02” respectively,
the remote keypad will be disabled, and the

STOP

key WILL NOT work.

Refer to the SM manual for more information on OEM Default settings.