LEESON NEMA 4x SCR Controls: 174107 User Manual

LEESON Software

Advertising
background image

POWER

SPEED

ON

OFF

0

1

22

3

4

5 6

7

8

9

1

1

2

5

6

3

4

CUSTOMER SUPPLIED

WATERTIGHT CORD

CONNECTORS (2)

S P E E D M A S T E R

®

®

ADJUSTABLE SPEED

DC MOTOR CONTROL

S T E P # 2

REMOVE THE FIVE (5)

PHILLIPS SCREWS ON

THE BOTTOM PLATE.

S T E P # 1

NOTE: THE TWO SHORTER

SCREWS (#6 - 32 x 2 ½) ON

THE FRONT CASE ARE USED

AT HOLE LOCATIONS 5 & 6.

REMOVE THE SIX (6)

PHILLIPS SCREWS ON

THE FRONT CASE.

CUSTOMER SUPPLIED

WATERTIGHT CORD

CONNECTORS (2)

BOTTOM PLATE

D O N O T R E M O V E

THE THREE (3) SCREWS SECURING

THE BOTTOM PLATE TO THE HEATSINK

4

5

2

1

3

ƽ

ƽ

FIELD OUTPUT

CONNECTIONS

The field output is for shunt
wound motors only. Do not

make any connections to

F1 and F2 when using a

permanent magnet (PM) motor.

For field motor connections,

see "Field Voltage" in

Specifications box below.

S T E P # 3

WIRE THE CONTROL

AS SHOWN THROUGH

THE CONDUIT HOLES

IN THE BOTTOM PLATE.

S T E P # 4

ASSURE THAT THE

VOLTAGE SWITCH

SETTINGS ARE CORRECT

(SW501 & SW502)

S T E P # 5

REPLACE SIX SCREWS

ON FRONT CASE &

FIVE SCREWS ON

BOTTOM PLATE.

ARMATURE VOLTAGE

SWITCH (SW501)

90 or 180 VDC

AC LINE VOLTAGE

SWITCH (SW502)

115 or 230 VAC

L

2-11

5

L

2-2

30

L

1

A2

F2

A1

T501

F502

MO

V

50

2

MOV501

R50

2

C503

SW501

230 - 115

S3

S

2

S

1

S

W

50

2

115 VAC

LINE

VOLTAGE

INPUT

(115 or 230 VAC)

EARTH

GROUND

(GREEN

SCREW)

MOTOR

ARMATURE

+

230 VAC

FIELD

OUTPUT

ƽ

LEESON Electric

2100 Washington Street • Grafton, WI 53024-0241 U.S.A.

TEL: (262) 377-8810 • FAX: (262) 377-9025

Printed in the U.S.A. - August 2002 • Document #: 250-0357, Revision 0

Copyright 2002 by LEESON Electric - All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from LEESON.
The information and technical data in this document are subject to change without notice. LEESON and its Divisions make no warranty of any kind with respect to this material,
including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. LEESON and its Divisions assume no responsibility for any errors
that may appear in this document and make no commitment to update or to keep current the information in this document.

®

174102 & 174107 NEMA4X SCR MOTOR CONTROLS

AC Line Voltage . . .115 VAC or 230 VAC, ±10%, 50/60 Hz, single phase

Horsepower Range with 115 VAC applied . . . . . . . . . . . . . . . .1/8 - 1 HP

Horsepower Range with 230 VAC applied . . . . . . . . . . . . . . . .1/4 - 2 HP

Maximum Armature Current . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 ADC

Maximum Field Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ADC

Field Voltage

for 115 VAC Input . . . . . . .50 VDC (F1 to L1); 100 VDC (F1 to F2)

for 230 VAC Input . . . . . .100 VDC (F1 to L1); 200 VDC (F1 to F2)

Form Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.37 at base speed

Analog Input Voltage Range (signal must be isolated; S1 to S2):

for 0 - 90 VDC Armature Voltage . . . . . . . . . . . . . . . .0 - 1.4 VDC

for 0 - 180 VDC Armature Voltage . . . . . . . . . . . . . . .0 - 2.8 VDC

Input Impedance (S1 to S2) . . . . . . . . . . . . . . . . . . . . . . . . . . .3M ohms

Load Regulation . . . . . . . . . . . . . . . . . . . . . . . .1% base speed or better

Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NEMA 4X

174102 Non-Reversing Speed Control

1. Set the speed adjust dial to “0” (full CCW).
2. Apply AC line voltage.
3. Set the POWER switch to the ON position.
4. Slowly advance the speed adjust potentiometer CW.

The motor slowly accelerates as the potentiometer is
turned CW. Continue until the desired speed is reached.

5. To coast the motor to a stop, turn the speed adjust

potentiometer to “0” or set the POWER switch to the
OFF position.

174107 Reversing Speed Control

1. Set the FORWARD/OFF/REVERSE switch to the OFF

position.

2. Set the speed adjust potentiometer to “0” (full CCW).
3. Apply AC line voltage.
4. Set the FOWARD/OFF/REVERSE switch to the desired

direction of rotation.

5. Slowly advance the speed adjust potentiometer CW.

The motor slowly accelerates as the potentiometer is
turned CW. Continue until the desired speed is reached.

6. To coast the motor to a stop, turn the speed adjust

potentiometer to “0” or set the
FORWARD/OFF/REVERSE switch to the OFF position.

S P E C I F I C A T I O N S

O P E R A T I O N

C O N N E C T I O N S

7. To reverse direction:

a. Set the FORWARD/OFF/REVERSE switch to the OFF

position.

b. After the motor comes to a complete stop, set the

FORWARD/OFF/REVERSE switch to the desired direction of
rotation.

Q U I C K S T A R T G U I D E