3. Connection

3.1. Cabling

ƒ Twisted-pair segment can be use unshielded twisted pair (UTP)

or shielded twisted pair (STP) cabling. The cable must comply
with the IEEE 802.3u 100Base TX standard for Category 5. The
cable between the converter and the link partner (switch, hub,
workstation, etc.) must be less than 100 meters (328 ft.) long.

ƒ Fiber segment using multi-mode connector type must use 50 or

62.5/125 um multi-mode fiber cable. You can connect two
devices up to a 2-kilometer (6,562 ft.) distance.

ƒ Fiber segment using single-mode connector type must use

8/125 or 9/125 um single-mode fiber cable. You can connect two
devices in the distance of 30 Kilometers in full duplex operation.
For half-duplex operation, the recommended maximum distance
is 412 meters (1,352 ft.)

3.2. RJ-45

Port

RJ-45 Port (Auto MDI/MDIX): the Ethernet RJ-45 will auto-sense for
10Base-T or 100Base-TX connections. Auto MDI/MDIX means that
you can connect to another Switch or workstation without changing
non-crossover or crossover cabling. See the below figures for
straight through and crossover cable schematic.

Pin Number

Assignment

1 Tx+
2 Tx-
3 Rx+
6 Rx-

RJ-45 Pin Assignments